lPrise cover loose using screwdriver in positionMAKING THE ELECTRICAL CONNECTIONS
(1) then lever off with screwdriver in position (2)
at either side. See Fig. 6.
Important: Switch off at mains, miniature circuit
breaker and, if appropriate, remove fuse before
commencing any electrical work.
PREPARING CABLE
We recommend you use a new length of cable to
ensure your safety.
lEnsure you have the correct length of cable
appropriate to the wiring method you are using.(2)
When fitting new cable allow sufficient cable for
removal of the unit at a later date, should it be
necessary.Terminal
(1)
lScore, but do not cut through, around theScrewdriver
sheathing with a knife 100mm (4in) from eachFig. 6
end of the cable and break through to the
encased wires by bending the cable backwards lLift cover and remove screw from cable clamp.
and forwards to fatigue the sheathing.See Fig. 7.
lCarefully score down from each end of the cable
sheathing along the length of the bare earth wire (if a
cut was made along the length of the live and neutral
wires, it might cut into their sheathing) to the cuts
already made.
lCarefully prise open the sheathing at each end of
the cable to expose the encased wiring. Cable
Clamping
TO REMOVE COVER OF MAINS TERMINAL Block
From the rear of the cooker, remove mains input
terminal cover to gain access to terminal block.
Fig. 7
lFirst remove retaining screw with pozidrive
screwdriver. See Fig. 5.
Pozidrive
Screwdriver
Fig. 5
11 |